18.1

Function blocks | L_ComparePhi_3

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.30

L_ComparePhi_3

This FB compares two angle signals.

• Comparison operation, hysteresis and window size can be parameterised.

Inputs

Outputs

Parameter

Identifier

Data type

Information/possible settings

dnIn1_p

DINT

Input signal 1

dnIn2_p

DINT

Input signal 2

Identifier

Data type

Value/meaning

bOut

BOOL

Status signal "Comparison statement is true"

TRUE The statement of the selected comparison mode is true.

Parameter

Possible settings

Info

C01670/3

Function selection

1 dnIn1 = dnIn2
2 dnIn1 > dnIn2
3 dnIn1 < dnIn2
4 |dnIn1| = |dnIn2|
5 |dnIn1| > |dnIn2|
6 |dnIn1| < |dnIn2|

C01671/3

0

Incr.

1073741824 Hysteresis

• Lenze setting: 0 incr.

C01672/3

0

Incr.

1073741824 Window

• Lenze setting: 0 incr.