C01065 | l_switchpoint_1: running time, C01066 | l_switchpoint_1: status, C01067 | inversion of gearbox stages – Lenze 8400 User Manual

Page 976: C01067/1, 16 parameter reference

Advertising
background image

16

Parameter reference

16.2

Parameter list | C01065

976

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01065

C01066

C01067

Parameter | Name:

C01065 | L_SwitchPoint_1: Running time

Data type: UNSIGNED_16

Index: 23510

d

= 5BD6

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0

ms

60000

Subcodes

Lenze setting

Info

C01065/1

0 ms

L_SwitchPoint_1

: Running time 1

C01065/2

0 ms

L_SwitchPoint_1

: Running time 2

C01065/3

0 ms

L_SwitchPoint_1

: Running time 3

C01065/4

0 ms

L_SwitchPoint_1

: Running time 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01066 | L_SwitchPoint_1: Status

Data type: INTEGER_16

Index: 23509

d

= 5BD5

h

From version 12.00.00

Selection list

0 OK

10 FB not active

100 Switching points not plausible

Subcodes

Info

C01066/1

L_SwitchPoint_1

: Status 1

C01066/2

L_SwitchPoint_1

: Status 2

C01066/3

L_SwitchPoint_1

: Status 3

C01066/4

L_SwitchPoint_1

: Status 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01067 | Inversion of gearbox stages

Data type: UNSIGNED_8

Index: 23508

d

= 5BD4

h

From version 12.00.00

Selection list

0 not inverted
1 inverted
2 Automatically from MCK

Subcodes

Lenze setting

Info

C01067/1

0: Not inverted

L_PhiIntegrator_1

: Invert. gearbox nSet_v

C01067/2

0: Not inverted

L_DFSET_1

: Invert. gearbox nSet_v

C01067/3

0: Not inverted

L_CalcDiameter_1

: Invert. gearbox nMotorSpeedAct_v

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising