5

Motor control (MCTRL)

5.4

V/f characteristic control (VFCplus)

162

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.4.3.6

Defining a user-defined V/f characteristic

For individual adaptation of the motor magnetisation to the actual application, the motor control

"10: VFCplus: V/f definable" with a freely definable characteristic can be selected in

C00006

as an

alternative if the linear and quadratic characteristics are not suitable.

• The 11 grid points (voltage/frequency values) of the characteristic are selected via the 11

subcodes of

C00967

and

C00968

.

• It is necessary to set all 11 grid points by means of corresponding subcodes.
• If fewer grid points (voltage/frequency values) are needed, this can be achieved indirectly by

ascribing the same voltage and frequency values to consecutive grid points.

Example: C00967/3 = C00967/4 and C00968/3 = C00968/4

• The grid points can be specified in any sequence. Internally, they are automatically ordered

from the minimum to the maximum frequency value.

• Above the maximum and below the minimum frequency, the previous rise is continued until

the maximum output voltage.

• In the Lenze setting, the 11 grid points represent a linear characteristic.

• 3-phase devices: Output voltage 400 V at f = 50 Hz
• 1-phase devices: Output voltage 230 V at f = 50 Hz

[5-7]

Freely definable characteristic (Lenze setting for 3-phase devices)

Note!

The V/f base frequency (

C00015

) and the V

min

boost (

C00016

) no longer exert an

influence if this motor control is chosen.

P1

P2

P3

P4

P5

P6

P7

P8

P9

P10

P11

V

400 V

320 V

240 V

160 V

80 V

0 V

80 V

160 V

240 V

320 V

400 V

f

-50 Hz

-40 Hz

-30 Hz

-20 Hz

-10 Hz

0 Hz

10 Hz

20 Hz

30 Hz

40 Hz

50 Hz

U [V]

160

0

f [Hz]

240

320

400

10

20

30

40

50

-50

-40

-30

-20

-10

80

C00967/1