Parameter reference

16.2

Parameter list | C02298

1046

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02298

C02299

C02300

Parameter | Name:

C02298 | LS_WriteParamList: Flying restart fct: Int. time

Data type: UNSIGNED_16

Index: 22277

d

= 5705

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.0

ms

6000.0

Subcodes

Lenze setting

Info

C02298/1

300.0 ms

LS_WriteParamList

: c993_val1

C02298/2

300.0 ms

LS_WriteParamList

: c993_val2

C02298/3

300.0 ms

LS_WriteParamList

: c993_val3

C02298/4

300.0 ms

LS_WriteParamList

: c993_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C02299 | LS_WriteParamList: Flying restart fct.: Current

Data type: INTEGER_16

Index: 22276

d

= 5704

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C02299/1

25.00 %

LS_WriteParamList

: c994_val1

C02299/2

25.00 %

LS_WriteParamList

: c994_val2

C02299/3

25.00 %

LS_WriteParamList

: c994_val3

C02299/4

25.00 %

LS_WriteParamList

: c994_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02300 | LS_WriteParamList: SLPSM: Controlled current setpoint

Data type: UNSIGNED_16

Index: 22275

d

= 5703

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

5.00

%

400.00

Subcodes

Lenze setting

Info

C02300/1

100.00 %

LS_WriteParamList

: c995_s1_val1

C02300/2

100.00 %

LS_WriteParamList

: c995_s1_val2

C02300/3

100.00 %

LS_WriteParamList

: c995_s1_val3

C02300/4

100.00 %

LS_WriteParamList

: c995_s1_val4

C02300/5

20.00 %

LS_WriteParamList

: c995_s2_val1

C02300/6

20.00 %

LS_WriteParamList

: c995_s2_val2

C02300/7

20.00 %

LS_WriteParamList

: c995_s2_val3

C02300/8

20.00 %

LS_WriteParamList

: c995_s2_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100