11.9

Parameter data transfer

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.9.2.4

Error messages

In the event of an error, the addressed node generates a telegram with the "Error response" (0x80)

command.

• The telegram includes the index and subindex of the code where the error occurred.
• The error code is entered in bytes 5 ... 8.

• The error codes are standardised according to DS301, V4.02.
• The representation of the error codes is provided in reverse read direction (see example

below).

Example
Representation of error code "0x06 04 00 41" in bytes 5 ... 8:

1st byte

2nd byte

3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Command

Index

Subindex

Error code

0x80

(128)

LOW byte

HIGH byte

LOW word

HIGH word

LOW byte

HIGH byte

LOW byte

HIGH byte

1st byte

2nd byte

3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Command

Index

Subindex

Error code

0x41

0x00

0x04

0x06

Advertising