Basic drive functions (MCK)

8.7

Manual jog

510

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.7.2

Requesting the operating mode

Request for "manual jog" mode via the

MCK control word

:

If the MCKInterface is connected upstream to the Motion Control Kernel and if the operating mode

is requested at the

L_MckCtrlInterface

FB, the wOperationMode and bOperationMode_1...8 process

inputs are available.

8.7.3

Executing manual jogging

Control is exercised by means of bits 4 ... 7 in the

MCK control word

:

If the Motion Control Kernel is downstream from the MCKInterface in the circuit, the

L_MckCtrlInterface

FB provides the following process inputs for controlling the operating mode:

MCK control word

Bit 31

...

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

OpMode_Bit3

OpMode_Bit2

OpMode_Bit1

OpMode_Bit0

X

...

X

0

0

1

0

X = Status not significant

Manual jog

MCK control word

Bit 7

Bit 6

Bit 5

Bit 4

Release

LimitSwitch

ManExecute

2ndSpeed

ManJogNeg

ManJogPos

Stop manual jogging

0

X

0

0

Manual jog, right

• With speed 1 (

C01231/1

)

0

0

1

Manual jog, right

• With speed 2 (

C01231/2

)

1

Manual jog, left

• With speed 1 (

C01231/1

)

0

1

0

Manual jog, left

• With speed 2 (

C01231/2

)

1

No change in relation to previous state

X

1

1

Retract operated limit switch

1

0

0

0

X = Status not significant

Identifier

Data type

Information/possible settings

bManJogPos

bManJogNeg

BOOL

bManJogPos = TRUE: Manual jog right

bManJogNeg = TRUE: Manual jog left

Both inputs = TRUE: No change compared to previous state

Both inputs = FALSE: Stop manual jog

bManJogExecute2ndVel

BOOL

Change over to speed 2 for manual jog

FALSE Speed 1 (

C01231/1

) active.

TRUE Speed 2 (

C01231/2

) active.

bReleaseLimitSwitch

BOOL

Retract operated limit switch

TRUE Retract operated limit switch (in opposite direction)

Advertising