4 application and release time, Application and release time, 8basic drive functions (mck) – Lenze 8400 User Manual

Page 543: Danger

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

543

8

Basic drive functions (MCK)

8.12

Holding brake control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.12.2.4

Application and release time

[8-34] Definition of the application and release time with the example of the PM brake

Tip!
The application and release times do not only vary between the brake types but also

depend on the basic conditions in the plant:

• Parameters of the hardware (cable length, temperature, level of supply voltage etc.)
• Contact elements used (brake module or contactor at the digital output)
• Type of overvoltage limitation/suppressor circuit

For optimisation purposes, detect in individual cases the response times by measurement.

Danger!

A wrong setting of the application and release time can cause a faulty control of the

brake!

• If the application time is set too low, the controller is inhibited and the drive becomes

torqueless before the brake is applied completely.

C02589/1

: Application time

C02589/2

: Release time

CINH = controller inhibit

• Every mechanical holding brake comes

with a construction-conditioned

application and release time which must

be considered by the holding brake control

and is set in

C02589

.

• The application and release time of the

Lenze holding brake is indicated in the

supplied operating instructions in the

"Technical data" chapter.

• If the application and release times are too

long, this is uncritical in respect of safety

but leads to unnecessarily long delays

during cyclical braking processes.

t

t

Œ



t

CINH

bBRKReleaseOut

I

BRK

Advertising