Introduction: Parameterising the controller

2.3

General notes on parameters

36

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

General operation

[2-2]

Example: Changing parameters with the keypad

1. Use the / navigation keys to select the

desired menu.

• Use the / navigation keys to reach a

higher/lower menu level.

• Use the  function key to return to the

main menu.

2. Use the / navigation keys to select the

parameter to be set within a submenu.

3. In order to select another subcode in case of a

parameter with subcodes:

• Press the navigation key  to change tot he

editing mode for the subcode.

• Use the navigation keys to set the desired

subcode.

4. Use the  function key to switch over to the

editing mode.

5. Use the navigation keys to set the desired value.
6. Use the  function key to accept the change

and to leave the editing mode.

• Use the  function key to leave the editing

mode without accepting the change.

Load Lenze setting

C00002/001

Off / Finished

EDIT

Par1 8400 protec

SAVE

Code list

Go To Param

USER - Menu

Fixed setpoint 1

C00039/001

40.00 %

EDIT

Fixed setpoint 2

60.00 %

EDIT

C00039/00

2

Fixed setpoint 2

C00039/002

ESC

6

0.00 %

OK