4

Device control (DCTRL)

4.4

Internal interfaces | "LS_DriveInterface" system block

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.4.1

wCANControl/wMCIControl control words

The controller is controlled by a master control (e.g. IPC) via the wCanControl or wMCIControl control

word, respectively.

wCANControl: Control word via system bus (CAN)

• The process data word is provided at the wCanControl input via the upstream

LP_CanIn1

port

block.

• Display parameter:

C00136/2

wMCIControl: Control word via a plugged-in communication module (e.g. PROFIBUS)

• The process data word is provided at the wMCIControl input via the upstream

LP_MciIn1

port

block.

• Display parameter:

C00136/1

• The bit assignment for the wCanControl/wMCIControl control words can be seen from the table

below.

Note!

The assignment of bits 11 ... 13 and bit 15 depends on the technology application

selected in

C00005

!

• See description of the corresponding technology application.

Bit

Name

Function

Bit 0 SwitchOn

1 ≡ Change to the "

SwitchedOn

" device status

• This bit has to be set in the CAN AND MCI control word in order that the drive

changes to the "

SwitchedOn

" device state. In order to reach the

"

ReadyToSwitchOn

" state, it is sufficient to set the bit to 0 in of the two

control words.

Bit 1 DisableVoltage

1 ≡ Inhibit inverter control (pulse inhibit)

Bit 2 SetQuickStop

Activate quick stop (QSP)

Activate/deactivate quick stop ( 104)

Bit 3 EnableOperation

1 ≡ Enable controller (RFR)

• This bit must be set in CAN AND in the MCI control word, otherwise the

controller will be inhibited.

Bit 4 ModeSpecific_1

Reserved (currently not assigned)

Bit 5 ModeSpecific_2
Bit 6 ModeSpecific_3
Bit 7 ResetFault

1 ≡ Reset fault (trip reset)

• Acknowledge error message (if the error cause has been eliminated).

Bit 8 SetHalt

1 ≡ Activate stop function

• Stop drive via stopping ramp (in preparation).

Bit 9 reserved_1

Reserved (currently not assigned)

Bit 10 reserved_2
Bit 11 LenzeSpecific_1

Assignment depends on the selected technology application

• See description of the corresponding technology application.

Bit 12 LenzeSpecific_2
Bit 13 LenzeSpecific_3
Bit 14 SetFail

1 ≡ Set error (trip set)

Bit 15 LenzeSpecific_4

Assignment depends on the selected technology application

• See description of the corresponding technology application.