C00349 | setting - dip switch sw1, C00350 | can node address, Code – Lenze 8400 User Manual

Page 810: C00350, Or w, 16 parameter reference

Advertising
background image

16

Parameter reference

16.2

Parameter list | C00349

810

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00349

C00350

Parameter | Name:

C00349 | Setting - DIP switch SW1

Data type: UNSIGNED_16

Index: 24226

d

= 5EA2

h

DIP switch setting during last mains power-on

CANopen Option/CAN on board

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Address 1
Bit 1 Address 2
Bit 2 Address 4
Bit 3 Address 8
Bit 4 Address 16
Bit 5 Address 32
Bit 6 Address 64
Bit 7 CAN baud rate 1
Bit 8 CAN baud rate 2
Bit 9 CAN baud rate 4

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 CAN DIP switch at 24V-ON accepted

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00350 | CAN node address

Data type: UNSIGNED_8

Index: 24225

d

= 5EA1

h

Setting of the node address via parameters

• The node address can only be parameterised if the node address "0" is set via the DIP switches.

• A change in the node address will not be effective until a CAN Reset Node is performed.

CANopen Option/CAN on board

Setting range

(min. value | unit | max. value)

Lenze setting

1

127 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1