C02216 | ls_writeparamlist: slip compensation, C02217 | ls_writeparamlist: imax in motor mode, C02218 | ls_writeparamlist: imax in generator mode – Lenze 8400 User Manual

Page 1024: C02216/1, C02216/2, C02216/3, C02216/4, C02217/1, C02217/2, C02217/3

Advertising
background image

16

Parameter reference

16.2

Parameter list | C02216

1024

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02216

C02217

C02218

Parameter | Name:

C02216 | LS_WriteParamList: Slip compensation

Data type: INTEGER_16

Index: 22359

d

= 5757

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

-100.00

%

100.00

Subcodes

Lenze setting

Info

C02216/1

2.67 %

LS_WriteParamList

: c21_val1

C02216/2

2.67 %

LS_WriteParamList

: c21_val2

C02216/3

2.67 %

LS_WriteParamList

: c21_val3

C02216/4

2.67 %

LS_WriteParamList

: c21_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02217 | LS_WriteParamList: Imax in motor mode

Data type: UNSIGNED_16

Index: 22358

d

= 5756

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

A

655.35

Subcodes

Lenze setting

Info

C02217/1

47.00 A

LS_WriteParamList

: c22_val1

C02217/2

47.00 A

LS_WriteParamList

: c22_val2

C02217/3

47.00 A

LS_WriteParamList

: c22_val3

C02217/4

47.00 A

LS_WriteParamList

: c22_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02218 | LS_WriteParamList: Imax in generator mode

Data type: INTEGER_16

Index: 22357

d

= 5755

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C02218/1

100.00 %

LS_WriteParamList

: c23_val1

C02218/2

100.00 %

LS_WriteParamList

: c23_val2

C02218/3

100.00 %

LS_WriteParamList

: c23_val3

C02218/4

100.00 %

LS_WriteParamList

: c23_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising