16.2

Parameter list | C00134

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00134

C00136

Parameter | Name:

C00134 | L_NSet_1: Ramp smoothing

Data type: UNSIGNED_8

Index: 24441

d

= 5F79

h

The

L_NSet_1

FB: Configuration of the ramp rounding for the main setpoint

Selection list

(Lenze setting printed in bold)

Info

0 Off

Ramp rounding deactivated

1 PT1 behaviour

Ramp rounding with PT1 behaviour

• The corresponding S-ramp time must be set in

C00182

.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00136 | Communication control words

Data type: UNSIGNED_16

Index: 24439

d

= 5F77

h

Control words of the communication interfaces
Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 SwitchOn
Bit 1 DisableVoltage
Bit 2 SetQuickStop
Bit 3 EnableOperation
Bit 4 ModeSpecific_1
Bit 5 ModeSpecific_2
Bit 6 ModeSpecific_3
Bit 7 ResetFault
Bit 8 SetHalt
Bit 9 Reserved_1

Bit 10 Reserved_2
Bit 11 LenzeSpecific_1
Bit 12 LenzeSpecific_2
Bit 13 LenzeSpecific_3
Bit 14 SetFail
Bit 15 LenzeSpecific_4

Subcodes

Info

C00136/1

MCI control word

• Control word of the MCI communication interface

(communication module)

C00136/2

CAN control word

• Control word of the CAN communication interface

(X31/X32)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT