18.1.82

L_DT1_1

This FB differentiates signals. The function block can, for instance, be used to apply an acceleration

(dv/dt).

Inputs

Outputs

Parameter

Identifier

Data type

Information/possible settings

nIn_a

INT

Input signal

Identifier

Data type

Value/meaning

nOut_a

INT

Output signal

Parameter

Possible settings

Info

C00251

10

ms

5000 Time constant Tn

• Lenze setting: 1000 ms

C00252

-320.00

320.00 Gain factor Vp

• Lenze setting: 1.00

C00253

Note: The most significant bit determines

the sign of the value, the remaining bits

determine the numerical value.

Selection of sensitivity

• Depending on the selection, the

number of indicated higher-order

bits is evaluated.

• Lenze setting: 15 bit

1 15 bits

Bit 0 ... bit 14 are evaluated

2 14 bits

Bit 0 ... bit 13 are evaluated

3 13 bits

Bit 0 ... bit 12 are evaluated

4 12 bits

Bit 0 ... bit 11 are evaluated

5 11 Bit

Bit 0 ... bit 10 are evaluated

6 10 Bit

Bit 0 ... bit 9 are evaluated

7 9 Bit

Bit 0 ... bit 8 are evaluated