Basic drive functions (MCK)

8.4

Basic settings

482

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Operating mode
If the limit for the following error in

C01215/x

is set higher than "0.0000 units" and if the current

following error exceeds this limit over the time set in

C01244/x

:

• The error response set in

C00595/5

or

C00595/6

will be carried out (Lenze setting: "Warning").

• The error message "

Ck05: Error, following error 1

" or "

Ck06: Error, following error 2

" will be

entered into the logbook.

• The status output bFollowErrLim1 or bFollowErrLim2 at the SB

LS_MotionControlKernel

is set to

TRUE.