C01070 | l_dfset_1: angular trimming, C01071 | l_dfset_1: following error limit, C01072 | l_dfset_1: multiplier - angular trimming – Lenze 8400 User Manual

Page 978: C01073 | l_dfset_1: adjustment, 16 parameter reference

Advertising
background image

16

Parameter reference

16.2

Parameter list | C01070

978

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01070

C01071

C01072

C01073

Parameter | Name:

C01070 | L_DFSET_1: Angular trimming

Data type: INTEGER_32

Index: 23505

d

= 5BD1

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

-134217728

Incr.

134217728

Subcodes

Lenze setting

Info

C01070/1

0 incr.

L_DFSET_1

: Speed-dependent angle adjustment

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01071 | L_DFSET_1: Following error limit

Data type: UNSIGNED_32

Index: 23504

d

= 5BD0

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

10

Incr.

2147483647

Subcodes

Lenze setting

Info

C01071/1

32768 incr.

L_DFSET_1

: Following error limit

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01072 | L_DFSET_1: Multiplier - angular trimming

Data type: INTEGER_16

Index: 23503

d

= 5BCF

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

-20000

20000

Subcodes

Lenze setting

Info

C01072/1

1

L_DFSET_1

: Multiplier - angular trimming

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01073 | L_DFSET_1: Adjustment

Data type: UNSIGNED_8

Index: 23502

d

= 5BCE

h

From version 12.00.00

Setting range

(min. hex value | max. hex value)

0x00

0xFF

Value is bit-coded:

Info

Bit 0 Setpoint angle without gearbox

factor

Bit 1 Angle correction with polynomial

Subcodes

Lenze setting

Info

C01073/1

0x02

L_DFSET_1

: Adjustment

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising