Parameter reference

16.2

Parameter list | C01201

994

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01201

C01202

C01203

Parameter | Name:

C01201 | MCK: Cycle

Data type: INTEGER_32

Index: 23374

d

= 5B4E

h

From version 06.00.00

Cycle for Modulo measuring system

• When the cycle is set to 0 units (Lenze setting), the traversing range is unlimited (classical measuring system).

Activation of the Modulo measuring system

Setting range

(min. value | unit | max. value)

0.0000

units

214748.3647

Subcodes

Lenze setting

Info

C01201/1

0.0000 units

MCK: Cycle

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01202 | MCK: iM motor/process

Data type: UNSIGNED_16

Index: 23373

d

= 5B4D

h

Gearbox factor - motor

• Entry of the gearbox factor as numerator/denominator ratio (numerator = motor speed and denominator =

output speed of gearbox) or from the number of teeth of the gearbox arrangement.

Machine parameter

Setting range

(min. value | unit | max. value)

1

65535

Subcodes

Lenze setting

Info

C01202/1

1

MCK: iM: Numerator gearbox factor Z2

C01202/2

1

MCK: iM: Denominator gearbox factor Z1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01203 | MCK: iG motor/position encoder

Data type: UNSIGNED_16

Index: 23372

d

= 5B4C

h

Gearbox factor - position encoder

• Entry of the gearbox factor as numerator/denominator ratio, with numerator = motor speed and denominator

= position encoder speed.

Machine parameter

Setting range

(min. value | unit | max. value)

1

65535

Subcodes

Lenze setting

Info

C01203/1

1

MCK: iG: Numerator (motor speed)

C01203/2

1

MCK: iG: Denominator (encoder speed)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1