2 led status displays, Led status displays, Status displays – Lenze 8400 User Manual

Page 554: 9diagnostics & error management

Advertising
background image

9

Diagnostics & error management

9.2

LED status displays

554

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.2

LED status displays

Information on some operating statuses can quickly be obtained via LED displays:

[9-1]

LED display on the controller front panel

',

',

','2

','2

',

',

5'<

(55

9

6

%UDNH

%865'<

%86(55

/LQN

/LQN

66WDWH

6(UURU

6$FNQZ

6(QDEOH

'5

9



6WDWXV

&RP

6DIHW\

,2

,2

Labelling

Colour

Status

Description

DRV-RDY

green

On

Standard device ready for

operation

LED status displays of the

device status ( 556)

DRV-ERR

red

On

Warning/trouble/fault

24V-S

green

On

24-V voltage available

Brake

yellow

Off

Motor holding brake not triggered (applied)

On

Motor holding brake triggered (released)

LED status displays for communication

BUS-RDY

green

Off

Communication not initialised

Blinking

Communication has been established

On

Communication has stopped

BUS-ERR

red

Blinking

With PROFINET: Node detection

Fast blinking With PROFINET: Nodes not detected

On

Communication error

Link-1

Link-2

yellow

Off

Communication is not active

Blinking

Initialisation

Fast blinking With PROFINET:

Communication is active, telegrams are sent.

LED status displays for integrated safety

Note: The status of the safety option 10 is exclusively signalled via the "S-Enable" display.

S-State

green

Off

Communication between Standard device and safety

engineering is not possible

Blinking

Integrated safety is in service state

On

Communication between standard device and safety system

has been established

S-Error

red

Off

Error-free operation

Blinking

Integrated safety system is not supported by the standard

device

On

Warning/trouble/fault

S-Acknw

yellow

On

Acknowledgement of a parameter set acceptance is required

S-Enable

yellow

Blinking

Safety function system active (unsafe display)

On

Controller enabled

Advertising