16 parameter reference – Lenze 8400 User Manual

Page 1096

Advertising
background image

16

Parameter reference

16.3

Table of attributes

1096

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01041

L_SRFG_1..2 S-ramp time

Linear value

23534

5BEE

A

2

UNSIGNED_32

1000

C01042

L_SRFG_1..2 limitations of output values

Linear value

23533

5BED

A

4

INTEGER_16

100

C01045

L_ConvAP 1-3: numerator/denominator

Linear value

23530

5BEA

A

6

INTEGER_16

1

C01046

L_ConvPA 1-3: byDivision

Linear value

23529

5BE9

A

3

INTEGER_8

1

C01047

L_GearComp_1: Offset

Linear value

23528

5BE8

A

1

INTEGER_16

1

C01048

L_GearComp_1: Num_Denom

Linear value

23527

5BE7

A

2

INTEGER_16

1

C01049

L_CalcDiameter_1: Status

Linear value

23526

5BE6

A

1

INTEGER_16

1

C01050

L_CalcDiameter_1: Diameter recalculation Linear value

23525

5BE5

A

2

UNSIGNED_32

1000

C01051

L_CalcDiameter_1: Filter time constant

Linear value

23524

5BE4

A

1

UNSIGNED_16

1000

C01052

L_CalcDiameter_1: Web break monitoring Linear value

23523

5BE3

A

1

INTEGER_16

100

C01053

L_ProcessCtrl_1: Controller times

Linear value

23522

5BE2

A

5

UNSIGNED_16

1000

C01054

L_ProcessCtrl_1: System deviation

Linear value

23521

5BE1

A

2

INTEGER_16

100

C01055

L_ProcessCtrl_1: Correcting variable

limitation

Selection list

23520

5BE0

A

1

UNSIGNED_8

1

C01056

L_ProcessCtrl_1: Controller gain

Linear value

23519

5BDF

A

1

UNSIGNED_16

100

C01057

L_CalcDiameter_1: Current diameter

Linear value

23518

5BDE

A

1

UNSIGNED_32

1000

C01058

L_PosCtrlLin_1-2: bDisable

Selection list

23517

5BDD

A

2

UNSIGNED_8

1

C01059

L_PosCtrlLin 1-2: Positioning behaviour

Selection list

23516

5BDC

A

2

UNSIGNED_8

1

C01060

L_PosCtrlLin 1-2: Ramps

Linear value

23515

5BDB

A

6

INTEGER_32

1000

C01061

L_PosCtrlLin 1-2: Traversing speed

Linear value

23514

5BDA

A

4

INTEGER_16

1

C01062

L_SwitchPoint_1: Dead time

Linear value

23513

5BD9

A

4

UNSIGNED_16

1

C01063

L_SwitchPoint_1: Hysteresis

Linear value

23512

5BD8

A

4

UNSIGNED_16

1

C01064

L_SwitchPoint_1: CenterMode

Selection list

23511

5BD7

A

4

UNSIGNED_8

1

C01065

L_SwitchPoint_1: Running time

Linear value

23510

5BD6

A

4

UNSIGNED_16

1

C01066

L_SwitchPoint_1: Status

Selection list

23509

5BD5

A

4

INTEGER_16

1

C01067

Inversion of gearbox stages

Selection list

23508

5BD4

A

3

UNSIGNED_8

1

C01068

L_SwitchPoint_1: Invert

Bit coded

23507

5BD3

A

1

UNSIGNED_16

1

C01069

L_DFSET_1: Ramp settings

Linear value

23506

5BD2

A

2

UNSIGNED_16

1

C01070

L_DFSET_1: Angular trimming

Linear value

23505

5BD1

A

1

INTEGER_32

1

C01071

L_DFSET_1: Following error limit

Linear value

23504

5BD0

A

1

UNSIGNED_32

1

C01072

L_DFSET_1: Multiplier - angular trimming Linear value

23503

5BCF

A

1

INTEGER_16

1

C01073

L_DFSET_1: Adjustment

Bit coded

23502

5BCE

A

1

UNSIGNED_8

1

C01074

L_DFSET_1: Zero pulse divider

Linear value

23501

5BCD

A

2

UNSIGNED_16

1

C01075

L_DFSET_1: Synchronisation mode

Selection list

23500

5BCC

A

1

UNSIGNED_8

1

C01076

L_DFRFG_1: Times

Linear value

23499

5BCB

A

2

UNSIGNED_32

1000

C01077

L_DFRFG_1: Max. speed-up

Linear value

23498

5BCA

A

1

INTEGER_16

1

C01078

L_DFRFG_1: Following error

Linear value

23497

5BC9

A

1

UNSIGNED_32

1

C01079

L_DFRFG_1: Synchronisation window

Linear value

23496

5BC8

A

1

UNSIGNED_16

1

C01080

L_DFRFG_1: Offset

Linear value

23495

5BC7

A

1

INTEGER_32

1

C01081

L_DFRFG_1: Sync. direction / TP function

Selection list

23494

5BC6

A

1

UNSIGNED_8

1

C01082

LS_WriteParamList: Execute Mode

Selection list

23493

5BC5

E

1

UNSIGNED_8

1

C01083

LS_WriteParamList: Error status

Linear value

23492

5BC4

E

1

UNSIGNED_16

1

C01084

LS_WriteParamList: Error line

Linear value

23491

5BC3

E

1

UNSIGNED_8

1

C01085

LS_WriteParamList: Index

Linear value

23490

5BC2

A

32

INTEGER_32

1000

C01086

LS_WriteParamList: WriteValue_1

Linear value

23489

5BC1

A

32

INTEGER_32

1

C01087

LS_WriteParamList: WriteValue_2

Linear value

23488

5BC0

A

32

INTEGER_32

1

C01088

LS_WriteParamList: WriteValue_3

Linear value

23487

5BBF

A

32

INTEGER_32

1

C01089

LS_WriteParamList: WriteValue_4

Linear value

23486

5BBE

A

32

INTEGER_32

1

C01090

LS_ParReadWrite 1-6: Index

Linear value

23485

5BBD

A

6

INTEGER_32

1000

C01091

LS_ParReadWrite 1-6: Cycle time

Selection list

23484

5BBC

A

6

UNSIGNED_16

1

Code

Name

Type

Index

Data

dec

hex

DS

DA

DT

Factor

CINH

Grayed out = display parameter (read access only)

Advertising