14 drive-based safety – Lenze 8400 User Manual

Page 714

Advertising
background image

14

Drive-based safety

14.4

Internal interfaces | system block "LS_SMInterface"

714

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.4.4

Transferring the control information to the application

In the simplest case, you only have to go to the I/O level in the FB editor and connect the wControl

output of the LS_SMInterface system block with the wSMControl input of the application block:

On the application level, the wSMControl input is connected with the motion control kernel. The

motion control kernel evaluates the transmitted control information and activates the required

motion sequence (e.g. braking).

Related topics:

Interface to safety system

( 453)

Note!

At present, the Motion Control Kernel only evaluates bit 0 (SS1). When this safety

function is requested, the drive will be decelerated to standstill along the stop ramp set

in

C02610/3

.

Additional functions are in preparation.