Introduction: Parameterising the controller

2.4

Device access protection

44

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2.4.2

Device personalisation

The device personalisation serves to connect the controller to the memory module by means of a

binding ID. If the device personalisation is active, write/read actions between the controller and the

memory module are only executed if both components have identical binding IDs.

If, for instance, a parameter set has been loaded from the memory module when the device

personalisation was active, this parameter set cannot be saved to another memory module that has

a different binding ID or no binding ID at all.

• Hence, a parameter set cannot be copied from a personalised memory module to a non-

personalised memory module!

The following two types are distinguished during the check:

• If a different binding ID is detected during switch-on of the controller (during device

initialisation):

• The "Fault" error response is returned.
• The "

PS10: Invalid memory module binding

" error message is entered into the logbook.

• If a different binding ID is detected during the execution of a device command for

loading/saving the parameter set:

• The loading/saving process is not carried out.
• A corresponding status for the device command is output in

C00003

.

Short overview of the relevant parameters for device personalisation:

Lenze delivery status:

Operation at the customer's site:

Impermissible replacement by the

end user:

No binding ID has been set.

Customer sets binding ID for device

personalisation purposes.

If device personalisation is active:

A replacement of the controller or

the memory module results in an

error message if the binding ID is

incorrect or not available.

Parameter

Info

Lenze setting

C00505/2

Binding ID

• The binding ID must have a length of 4 ... 16 characters.

• The binding ID may consist of any character. However, this is not

sensible. Recommended characters are: lower case letters (a - z),

upper case letters (A - Z) and digits (0 - 9).

Note:

After the execution of one of the device commands listed below, this

parameter provides the current binding ID status:

OFF No binding ID has been set.

ON Binding ID has been set.

Device commands

Before the following device commands are executed, enter the corresponding binding ID in

C00505/2

.

Highlighted in grey = display parameter

---

---

ABC