C00710 | la_tabpos: analog connection list, C00710, 16 parameter reference – Lenze 8400 User Manual

Page 882

Advertising
background image

16

Parameter reference

16.2

Parameter list | C00706

882

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00706

C00710

Parameter | Name:

C00706 | LA_NCtrl_Out digital signal list

Data type: UNSIGNED_16

Index: 23869

d

= 5D3D

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00710 | LA_TabPos: Analog connection list

Data type: UNSIGNED_16

Index: 23865

d

= 5D39

h

Connection parameters for "Table positioning" application: 16-bit inputs

• Selection of the 16 bit output signals to be connected to the 16 bit input signals

• The selection list contains all 16 bit output signals which can be assigned to the 16 bit inputs displayed by the

subcodes.

Selection list
See

selection list - analog signals

Subcodes

Lenze setting

Info

C00710/1

0: Not connected

LA_TabPos

: wCanDriveControl

Input for control word from CAN to device control

C00710/2

0: Not connected

LA_TabPos

: wMciDriveControl

Input for control word from communication interface to

device control

C00710/3

0: Not connected

LA_TabPos

: nTorqueMotLim_a

Input for maximum torque in motor mode

C00710/4

0: Not connected

LA_TabPos

: nTorqueGenLim_a

Input for maximum torque in generator mode

C00710/5

0: Not connected

LA_TabPos

: nMainSetValue_a

Input for main speed setpoint

C00710/6

0: Not connected

LA_TabPos

: nAuxSetValue_a

Input for additional speed setpoint

C00710/7

0: Not connected

LA_TabPos

: wMckCtrl1

Input for MCK control word 1

C00710/8

0: Not connected

LA_TabPos

: wMckCtrl2

Input for MCK control word 2

C00710/9

0: Not connected

LA_TabPos

: wMckOperationMode

Input for selection of MCK operating mode

C00710/10

0: Not connected

LA_TabPos

: wPosProfileMode

Input for selection of MCK positioning mode in

positioning mode

C00710/11

0: Not connected

LA_TabPos

: wPosProfileNo

Input for MCK positioning profile number in positioning

mode

C00710/12

0: Not connected

LA_TabPos

: nGPAnalogSwitchIn1_a

Input for analog switch - analog signal 1

C00710/13

0: Not connected

LA_TabPos

: nGPAnalogSwitchIn2_a

Input for analog switch - analog signal 2

C00710/14

0: Not connected

LA_TabPos

: nGPArithmetikIn1_a

Input for arithmetic function - analog signal 1

C00710/15

0: Not connected

LA_TabPos

: nGPArithmetikIn2_a

Input for arithmetic function - analog signal 2

C00710/16

0: Not connected

LA_TabPos

: nGPMulDivIn_a

Input for analog signal for multiplication/division

C00710/17

0: Not connected

LA_TabPos

: nGPCompareIn1_a

Input for comparison operation - analog signal 1

Advertising