C02256 | ls_writeparamlist: moment of inertia, C02260 | ls_writeparamlist: speed sensor selection, C02256/1 – Lenze 8400 User Manual

Page 1036: C02256/2, C02256/3, C02256/4, C02260/1, C02260/2, C02260/3, C02260/4

Advertising
background image

16

Parameter reference

16.2

Parameter list | C02256

1036

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02256

C02260

C02261

Parameter | Name:

C02256 | LS_WriteParamList: Moment of inertia

Data type: UNSIGNED_32

Index: 22319

d

= 572F

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

kg cm^2

6000000.00

Subcodes

Lenze setting

Info

C02256/1

0.00 kg cm^2

LS_WriteParamList

: c273_val1

C02256/2

0.00 kg cm^2

LS_WriteParamList

: c273_val2

C02256/3

0.00 kg cm^2

LS_WriteParamList

: c273_val3

C02256/4

0.00 kg cm^2

LS_WriteParamList

: c273_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02260 | LS_WriteParamList: Speed sensor selection

Data type: UNSIGNED_8

Index: 22315

d

= 572B

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Selection list

0 No sensor
1 Sensor signal FreqIn12
2 Encoder signal FreqIn56

Subcodes

Lenze setting

Info

C02260/1

0: No sensor

LS_WriteParamList

: c495_val1

C02260/2

0: No sensor

LS_WriteParamList

: c495_val2

C02260/3

0: No sensor

LS_WriteParamList

: c495_val3

C02260/4

0: No sensor

LS_WriteParamList

: c495_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02261 | LS_WriteParamList: SC: Field feedforward control

Data type: UNSIGNED_16

Index: 22314

d

= 572A

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

%

600

Subcodes

Lenze setting

Info

C02261/1

200 %

LS_WriteParamList

: c576_val1

C02261/2

200 %

LS_WriteParamList

: c576_val2

C02261/3

200 %

LS_WriteParamList

: c576_val3

C02261/4

200 %

LS_WriteParamList

: c576_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising