C02652 | settings of measuring system, C02810 | tp: edge selection, C02810/4 – Lenze 8400 User Manual

Page 1058: C2652, C02810/x, Tting of, Go to, And se, 16 parameter reference

Advertising
background image

16

Parameter reference

16.2

Parameter list | C02652

1058

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02652

C02810

Parameter | Name:

C02652 | Settings of measuring system

Data type: UNSIGNED_16

Index: 21923

d

= 55A3

h

From version 12.00.00

Setting range

(min. hex value | max. hex value)

Lenze setting

0x0000

0xFFFF 0x0000 (decimal: 0)

Value is bit-coded: (= bit set)

Info

Bit 0  Actual MCTRL position received at

mains switch-off

Bit 1  Delete reference when machine data

is changed

Status bit "HomPosAvailable"

Bit 2  Reserved
Bit 3  Reserved
Bit 4  Reserved
Bit 5  Reserved
Bit 6  Reserved
Bit 7  Reserved
Bit 8  Reserved
Bit 9  Reserved

Bit 10  Reserved
Bit 11  Reserved
Bit 12  Reserved
Bit 13  Reserved
Bit 14  Reserved
Bit 15  Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02810 | TP: Edge selection

Data type: UNSIGNED_8

Index: 21765

d

= 5505

h

From version 06.00.00

Touch-probe detection

Selection list

0 Off
1 Rising
2 Falling
3 Rising and falling

Subcodes

Lenze setting

Info

C02810/1

0: Off

Reserved

C02810/2

0: Off

Reserved

C02810/3

0: Off

Reserved

C02810/4

0: Off

TPDigIn4: Edge selection

C02810/5

0: Off

TPDigIn5: Edge selection

C02810/6

0: Off

TPDigIn6: Edge selection

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1