18.1.166.4 Position/time-based cams

The setting of a running time in

C01065/x

higher 0 ms serves to realise "position/time-based cams":

If the drive reaches the switching range, the bOut switching output is set to TRUE and reset to FALSE

after the set switching time has elapsed.

[18-68] Position/time-based cams (here without switching hysteresis and dead time compensation)

If the switching range is left before the running time has expired, the bOut switching output is reset

to FALSE:

[18-69] Position/time-based cams: Behaviour when the switching range is left before the running time has expired

Tip!
Please note that for a resetting of the switching output the switching range must be left

first.