1 insert options for copied elements, Insert options for copied elements 5, 17 working with the fb editor – Lenze 8400 User Manual

Page 1145

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1145

17

Working with the FB Editor

17.4

Reconfiguring the predefined interconnection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.4.6.1

Insert options for copied elements

If interconnection elements have been copied to the clipboard, the »Engineer« will display a list of

all elements contained in the clipboard when selecting the command Insert in the Insert FB

interconnection dialog box:

The list shows the elements which can be added to the target interconnection, and the elements

which cannot be added.

• In the "Selection" column, you can check/uncheck the elements to be added.
• Connections are only inserted when the dialog box is closed, which applies to all modules

inserted so far. They are displayed as lines or flags, like in the original, but re-routed.

• The symbols in the Toolbar serve to execute the following functions:

Icon

Function
Add the selected elements to the interconnection

Show the elements to be added but are marked with an error or warning.

Show the elements not to be added and marked with an error or warning.

Show blocks

Show connections

Show parameters

Show comments

Show system elements

Show all

Print view

Print list