18
Function library
18.1
Function blocks | L_AnalogSwitch_3
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.6
L_AnalogSwitch_3
This function block switches between two analog input signals. The switching is controlled via a
boolean input signal.
Inputs
Outputs
Identifier
Data type
Information/possible settings
nIn1_a
INT
Input signal 1
nIn2_a
INT
Input signal 2
bSet
BOOL
Selection of the input signal for the output to nOut_a
FALSE nIn1_a
TRUE nIn2_a
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal