17 ls_parfix, 17 ls_parfix 5, Ls_parfix – Lenze 8400 User Manual
Page 1445: Ls_parfix_2, 18 function library
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
1445
18
Function library
18.2
System blocks | LS_ParFix
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.2.17
LS_ParFix
This system block outputs various fixed values (constants) to be used in the interconnection.
•
From version 12.00.00
, another LS_ParFix_2 system block is available which can be used e.g. in
the application level.
Outputs
Identifier
Data type
Value/meaning
bTrue
BOOL
1 ≡ TRUE
nPos100_a
INT
16384 ≡ + 100 %
nNeg100_a
INT
-16384 ≡ - 100 %
nPos199_99_a
INT
32767 ≡ + 199.99 %
nNeg199_99_a
INT
-32767 ≡ - 199.99 %
w65535
WORD
65535 ≡ 0xFFFF
wDriveCtrl
WORD
9 ≡ 0x0009
• Bit 0, SwitchOn = TRUE
• Bit 3, EnableOperation = TRUE
• All others: FALSE
See also:
wCANControl/wMCIControl control words
E7UXH