Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

339

6

I/O terminals

6.5

User-defined terminal assignment

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.5

User-defined terminal assignment

In order to individually adapt the preconfigured assignment of the input/output terminals to your

application, you can choose one of the following procedures:

A. In the »Engineer«:

• Change the terminal assignment on the Terminal assignment tab.
• Change the signal assignment on the Application Parameters tab, on the dialog level

OverviewSignal flow.

• Change the interconnections in the FB editor (on the I/O level).

B. In the »Engineer« or with the keypad:

• Change the parameters for signal configuration in the parameters list.

Tip!
First of all, select a Lenze configuration useful for the purpose at hand by going to

C00005

and selecting a technology application that matches your drive task and then going to

C00007

and selecting an appropriate control mode. You will then have an application for

which there is a signal flow, logical block links and terminal assignment.
We recommend using the »Engineer« for the implementation of comprehensive user-

defined drive solutions.

Note!

If you change the preconfigured assignment of the inputs/outputs, the terminal

assignment will be a user-defined one. In

C00007

, control mode "0: Interconnection

changed" will be shown.