8basic drive functions (mck) – Lenze 8400 User Manual
Page 486
Advertising
8
Basic drive functions (MCK)
8.4
Basic settings
486
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
In example 2, the setpoint holdback in the master is set to 2 ms. This removes the offset between
master and slave. Only time differences are visible due to the telegram runtimes on the bus.
[8-22] Example 2: Runtime behaviour with setpoint holdback = 2 ms
Setpoint at the output of the Motion Control Kernel (is transferred to the slaves via fieldbus)
Effective setpoint of the motor control in the master
Effective setpoint of the motor control in the slave
t