5

Motor control (MCTRL)

5.7

Sensorless vector control (SLVC)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.7.2.2

Torque control with speed limitation

A torque setpoint is defined for the drive system to be used during torque-controlled operation.

Unlike the

Speed control with torque limitation

, this control mode uses the speed controller for

speed limitation.

• Due to its limitation, the speed-controlled drive can only rotate within a speed range whose

positive speed is limited by nSpeedHighLimit_a and whose negative speed is limited by

nSpeedLowLimit_a.

• The speed is defined by the process.
• The torque setpoint is calculated directly from nTorqueSetValue_a.

From version 12.00.00 onwards,

the torque limitation is active via nTorqueMotLimit_a and

nTorqueGenLimit_a in this control mode, too, for the torque setpoint to be limited. The

torque limitation can be deactivated in

C2865/1

via bit 0 to obtain the previous function.

Note!

Absolute speed limitation to speed 0 min

-1

(nSpeedLowLimit_a or

nSpeedHighLimit_a = 0) is only possible

from version 12.00.00

.

Identifier

DIS code | data type

Information/possible settings

nTorqueSetValue_a

C00830/27

| INT

Torque setpoint / additive torque

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

nSpeedHighLimit_a

C00830/88

| INT

Upper speed limit for speed limitation

(only for torque-controlled operation)

• Scaling: 16384 ≡ 100 % rated speed (

C00011

)

nSpeedLowLimit_a

C00830/23

| INT

Lower speed limit for speed limitation

(only for torque-controlled operation)

• Scaling: 16384 ≡ 100 % rated speed (

C00011

)

nTorqueMotLimit_a

C00830/29

| INT

Torque limitation in motor mode

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

• Setting range: 0 … +199.99 %

• If keypad control is performed: Parameterisable via

C00728/1

.

nTorqueGenLimit_a

C00830/28

| INT

Torque limitation in generator mode

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

• Setting range: -199.99 ... 0 %

• If keypad control is performed: Parameterisable via

C00728/2

.

Advertising