C00187

C00188

C00189

Parameter | Name:

C00187 | Current AutoFailReset processes

Data type: UNSIGNED_8

Index: 24388

d

= 5F44

h

Data of the current number of "AutoFailReset" procedures

AutoFailReset function

Display range

(min. value | unit | max. value)

0

16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00188 | AutoFailReset configuration

Data type: UNSIGNED_8

Index: 24387

d

= 5F43

h

Setting which error messages are to be reset automatically.

AutoFailReset function

Selection list

(Lenze setting printed in bold)

Info

0 Off

No automatic error message reset

1 Fault + TroubleQSP

Error messages with the response "Fault" and

"TroubleQSP" are reset automatically

2 WarningLocked

Error messages with the response "WarningLocked" are

reset automatically

3 All locking

All "locking" error messages are reset automatically

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00189 | Resp. to too frequent AutoFailReset

Data type: UNSIGNED_8

Index: 24386

d

= 5F42

h

Response to exceeding the maximum number of "AutoFailReset" processes set in

C00186

.

AutoFailReset function

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1