104 l_muldiv_2, 104 l_muldiv_2 8, L_muldiv_2 – Lenze 8400 User Manual

Page 1318: 18 function library

Advertising
background image

18

Function library

18.1

Function blocks | L_MulDiv_2

1318

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.104

L_MulDiv_2

This FB multiplies the analog input signal with a parameterisable factor.

• The value of the factor is determined by a quotient consisting of numerator and denominator .
• The value output at nOut_a is limited to ±199.99 %.
• Division is not remainder considered.

Inputs

Outputs

Parameter

Function

Identifier

Data type

Information/possible settings

nIn1

INT

Input signal

Identifier

Data type

Value/meaning

nOut_a

INT

Product value (result of the multiplication)

• Internal limitation to ± 32767

Parameter

Possible settings

Info

C00679/1

-32767

32767 Counter

C00679/2

-32767

32767 Denominator

/B0XO'LYB

Q,QBD

Q2XWBD

&

&

“

“



nOut_a

nIn_a C00679/1

C00679/2

-------------------------

Ч

=