18 function library – Lenze 8400 User Manual

Page 1281

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1281

18

Function library

18.1

Function blocks | L_DigitalLogic_2

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Function "4: bOut = f (Truth table)"
When the function "4: bOut = f (truth table)" is selected in

C00822

, the output value bOut depends

on the truth table parameterised in

C00823/1...8

.

The following table shows which setting may be required in

C00823/1...8

to realise the logic

operations NAND, NOR, XOR and XNOR:

C00823/1...8

Truth table for function "4: bOut = f

(truth table)"

• Each of the eight possible input

combinations can be assigned to

the output value FALSE or TRUE.

• For an application example see

the following section.

0 FALSE
1 TRUE

Input signals

Output

Parameter setting for logic operation:

bIn3

bIn2

bIn1

bOut

NAND

NOR

XOR

XNOR

0

0

0

C00823/1

=

1

1

0

1

0

0

1

C00823/2

=

1

0

1

0

0

1

0

C00823/3

=

1

0

1

0

0

1

1

C00823/4

=

1

0

0

1

1

0

0

C00823/5

=

1

0

1

0

1

0

1

C00823/6

=

1

0

0

1

1

1

0

C00823/7

=

1

0

0

1

1

1

1

C00823/8

=

0

0

0

1

Parameter

Possible settings

Info

Advertising