C01204

C01205

C01206

Parameter | Name:

C01204 | MCK: Feed constant

Data type: INTEGER_32

Index: 23371

d

= 5B4B

h

The feed constant corresponds to the movement of the machine during one revolution of the gearbox output shaft.

• The value is entered in application units referred to one revolution.

Machine parameter

Setting range

(min. value | unit | max. value)

Lenze setting

0.0001

units/rev.

214748.3647 360.0000 units/rev.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01205 | MCK: Position resolution

Data type: INTEGER_32

Index: 23370

d

= 5B4A

h

Display of the number of increments corresponding to one unit.

• 1 motor revolution ≡ 65536 increments

Machine parameter

Display range

(min. value | unit | max. value)

0.0000

Incr./unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01206 | MCK: Mounting direction

Data type: UNSIGNED_8

Index: 23369

d

= 5B49

h

Inversion for mirrored motor and encoder mounting

Machine parameter

Selection list

0 not inverted
1 inverted

Subcodes

Lenze setting

Info

C01206/1

0: Not inverted

Motor mounting direction

• Setting for motor mounting turned by 180°.

C01206/2

0: Not inverted

Position encoder mounting direction

• Setting for position encoder system mounting turned

by 180°.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT