C00101 | add. accel. time x, C00103 | add. decel. time x, C00101/1 – Lenze 8400 User Manual

Page 763: C00103/1, 16 parameter reference

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

763

16

Parameter reference

16.2

Parameter list | C00101

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00101

C00103

Parameter | Name:

C00101 | Add. accel. time x

Data type: UNSIGNED_32

Index: 24474

d

= 5F9A

h

The

L_NSet_1

: FB: Additional acceleration times for the main setpoint

• The additional acceleration times set here can be selected via the binary inputs bTI1 ... bTI8 of the

L_NSet_1

FB.

Setting range

(min. value | unit | max. value)

0.000

s

999.999

Subcodes

Lenze setting

Info

C00101/1

0.000 s

Add. accel. time 1 ... 15

C00101/...
C00101/15

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00103 | Add. decel. time x

Data type: UNSIGNED_32

Index: 24472

d

= 5F98

h

The

L_NSet_1

FB: Additional deceleration times for the main setpoint

• The additional deceleration times set here can be selected via the binary inputs bTI1 ... bTI8 of the

L_NSet_1

FB.

Setting range

(min. value | unit | max. value)

0.000

s

999.999

Subcodes

Lenze setting

Info

C00103/1

0.000 s

Add. decel. time 1 ... 15

C00103/...
C00103/15

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000