157 l_signalswitch32_1, 157 l_signalswitch32_1 3, L_signalswitch32_1 – Lenze 8400 User Manual

Page 1403: 18 function library

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1403

18

Function library

18.1

Function blocks | L_SignalSwitch32_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.157

L_SignalSwitch32_1

This FB switches between two input signals of the "DINT" data type. The switch-over is controlled by

means of a boolean input signal.

Inputs

Outputs

Identifier

Data type

Information/possible settings

dnIn1

DINT

Input signal 1

dnIn2

DINT

Input signal 2

bSet

BOOL

Selection of the input signal for the output at dnOut

FALSE dnIn1

TRUE dnIn2

Identifier

Data type

Value/meaning

dnOut

DINT

Output signal

/B6LJQDO6ZLWFKB

GQ,Q

GQ2XW

GQ,Q

E6HW





Advertising