144 l_pt1_2, 144 l_pt1_2 0, L_pt1_2 – Lenze 8400 User Manual
Page 1390: 18 function library
18
Function library
18.1
Function blocks | L_PT1_2
1390
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.144
L_PT1_2
This FB filters and delays analog signals.
• Filter time constant T can be set in
• The gain is defined with V
p
= 1.
Inputs
Outputs
Parameter
Function
[18-61] Filter time constant T of the first-order delay element
Identifier
Data type
Information/possible settings
nIn_a
INT
Input signal
Identifier
Data type
Value/meaning
nOut
INT
Output signal
Parameter
Possible settings
Info
0
ms
5000 Filter time constant
• The filter is not active with a
setting of "0 ms". The input signal
is passed through one-to-one to
the output.
• Lenze setting: 2000 ms
/B37B
)LOWHUWLPH
&
Q,QBD
Q2XWBD
T
V = 1
p
t