_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 11: <_Ln_>_TP
Procedure:
1. Movement in negative direction with start profile data set.
2. Reversing when the edge of the negative travel range limit switch is positive and, at the same
time, activation of search profile data set for continued reference searching.
3. Negative edge of the travel range limit switch enables home position detection.
4. Following edge of the touch probe sensor sets home position.
Touch probe
Negative travel range limit switch
Mode 11
<
Ln
>
TP
Offset path
Sequence profile (optional)
Start speed
Search speed
Profile speed
Lp
Inactive
Inactive
Active
Active
Active
Active
Ln
Inactive
Inactive
Inactive
Inactive
Inactive
Active
1
0
1