C01100

C01101

C01120

Parameter | Name:

C01100 | Function L_Counter 1-3

Data type: UNSIGNED_8

Index: 23475

d

= 5BB3

h

Selection of reset function
Selection list

0 Normal counting
1 Auto reset
2 Manual reset

Subcodes

Lenze setting

Info

C01100/1

0: Normal counting

L_Counter_1

: Function

C01100/2

0: Normal counting

L_Counter_2

: Function

C01100/3

0: Normal counting

L_Counter_3

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01101 | Comparison L_Counter 1-3

Data type: UNSIGNED_8

Index: 23474

d

= 5BB2

h

Selection of comparison operation
Selection list

0 Greater than or equal to
1 Less than or equal to
2 equal to

Subcodes

Lenze setting

Info

C01101/1

0: Greater than or equal to

L_Counter_1

: Comparison

C01101/2

0: Greater than or equal to

L_Counter_2

: Comparison

C01101/3

0: Greater than or equal to

L_Counter_3

: Comparison

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01120 | Sync signal source

Data type: UNSIGNED_8

Index: 23455

d

= 5B9F

h

Selection of the signal source for device synchronisation

• The drive can only be synchronised by one source.

Selection list

(Lenze setting printed in bold)

Info

0 Off

Synchronisation off

1 CAN on board

Synchronisation via CAN bus

Sync telegram

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1