4 time-based start of second speed, Time-based start of second speed, Time-based start of second speed ( 509) – Lenze 8400 User Manual

Page 509: 8basic drive functions (mck)

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

509

8

Basic drive functions (MCK)

8.7

Manual jog

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.7.1.4

Time-based start of second speed

If this function has been activated by means of bit 1 in

C01230

and a waiting time > "0 s" has been

set in

C01235/1

, an automatic change-over to manual jog speed 2 takes place when the manual jog

function is activated and after the waiting time has expired.

• When the waiting time is set = 0 s, the automatic change-over is deactivated.

[8-29] Time-based start of second speed

Tip!
By leaving the corresponding button for manual jog pressed down for longer than the

waiting time and parameterising manual jog speed 2 so that it is higher than manual jog

speed 1, you can enable longer distances to be travelled by means of manual jogging with

this function.

Time-based start deactivated

(

C01230

- bit 1 = 0; Lenze setting)

Time-based start activated

(

C01230

- bit 1 = 1)

C01231/1

: Manual jog: Speed 1

C01231/2

: Manual jog: Speed 2

C01235/1

: Waiting time 2nd speed (Lenze setting: 5 s)

n

t

TRUE

FALSE

ManJogPos

t

Œ



Ž

n

t

TRUE

FALSE

ManJogPos

t

Œ



Ž

Advertising