18 function library – Lenze 8400 User Manual

Page 1266

Advertising
background image

18

Function library

18.1

Function blocks | L_DFSET_1

1266

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01073/1

Setting is bit coded:

Setting

• Lenze setting: 0x02

Bit 0 Setpoint angle without gearbox

factor

0 = Evaluation of the setpoint angle

with gearbox factor.

1 = Evaluation of the setpoint angle

without gearbox factor.

Bit 1 Angle correction with polynomial

0 = Angle correction without

downstream polynomial.

1 = Angle correction with

downstream polynomial.

Bit 2 Reserved

...

Bit 7

C01074/1

0

16384 Divisor for actual value zero pulse

• Number of signals to be received

at least until synchronisation gets

active.

• Initialisation: 0

C01074/2

0

16384 Divisor for setpoint zero pulse

• Number of signals to be received

at least until synchronisation gets

active.

• Initialisation: 0

C01075/1

Synchronisation mode - mark

correction

0 Synchronisation inactive

Lenze setting

1 Permanent synchronisation without

enable via the bZeroPulse input

• Correction is executed over the

shortest possible path.

The synchronisation only takes place

after 2 setpoint pulses have been

received at the bSetTPReceived input.

(required pulse order: set-actual-set)

2 Permanent synchronisation only

with enable via the bZeroPulse input

• When bZeroPulse is set to TRUE, a

permanent zero pulse/touch

probe synchronisation is

executed.

• Correction is executed over the

shortest possible path.

10 One-time synchronisation

• An angular difference is

compensated over the shortest

possible path.

11 One-time synchronisation

• An angle difference is

compensated in CW direction.

12 One-time synchronisation

• An angular difference is

compensated in CCW direction.

13 One-time synchronisation

• An angular difference is

compensated over the shortest

possible path.

Synchronisation takes place after the

first setpoint pulse has been received

at the bSetTPReceived input and/or

actual value pulse at the

bActTPReceived input.

(Required clock sequence: Set/actual

or actual/set)

Parameter

Possible settings

Info