51 l_convw_1, 51 l_convw_1 1, L_convw_1 – Lenze 8400 User Manual
Page 1221: 18 function library
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
1221
18
Function library
18.1
Function blocks | L_ConvW_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.51
L_ConvW_1
This FB serves to convert analog signal forms. The following conversions per parameter can be
selected:
• [%] [incr/ms]
• [incr/ms] [%]
• Conversion via parameterisable factors
• Input signal is passed through without conversion
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
wIn
WORD
Input signal
Identifier
Data type
Value/meaning
wOut
WORD
Output signal
Parameter
Possible settings
Info
-2147483647
2147483647 Numerator
• Lenze setting: 1
-2147483647
2147483647 Denominator
• Lenze setting: 1
Selection of the conversion
0 wOut = wIn (no conversion)
1 [%] [incr/ms]
2 [incr/ms] [%]
3 wOut = wIn *
/B&RQY:B
Z2XW
Z,Q
'HQRPLQDWRU
&RQYHUVLRQ
&
&
&
1XPHUDWRU