Commissioning

3.10

PC manual control

92

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.10.4

Manual jog

In the "Manual jog" mode, the drive can be traversed manually in a clockwise or counter-clockwise

direction.

The change to the "Manual jog" mode can be made by selecting the correspondent option on the

Positioning tab:

• The profile parameters saved in the parameter set for the basic "manual control" function are

used:

How to traverse the drive manually in inching mode:

1. If the controller is still inhibited, enable the controller via the Enable controller button.

• Please note that the controller is only enabled if no other sources of a controller inhibit

(e.g. terminal RFR) are active.

If the controller is in the "OperationEnabled" status:

2. Click << Left or Right >> (and keep it pressed) to traverse the drive in the corresponding

direction of rotation.

You can find detailed information on the "Manual jog" mode in the chapter entitled

"Basic drive functions" in the subchapter "

Manual jog

".

( 505)

Parameter

Lenze setting

Info

Value Unit

Speed 1

(

C01231/1

)

360.0000 units/s

Speed for manual jog

Acceleration

(

C01232/1

)

720.0000 units/s

2

For accelerating and decelerating, different values can

be set so that smooth starting and quick stopping of the

drive can be implemented.

Delay

(

C01232/2

)

720.0000 units/s

2

S-ramp time

(

C01233/1

)

0.000 s

In order to reduce jerking, the two ramps can be set in

such a way that they are s-shaped. This is done by

entering a relative S-ramp time.