8basic drive functions (mck) – Lenze 8400 User Manual

Page 538

Advertising
background image

8

Basic drive functions (MCK)

8.12

Holding brake control

538

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of parameters for holding brake control:

Parameter

Info

Lenze setting

Value Unit

C02580

Holding brake: Operating mode

0: Brake control off

C02581/1

Holding brake: Switching threshold

5.00 %

C02581/2

Holding brake: Hyst. release

1.00 %

C02581/3

Holding brake: Hyst. close

1.00 %

C02581/4

Holding brake: FF control starting value 1

0 %

C02581/5

Holding brake: FF control starting value 2

0 %

C02582

Holding brake: Setting

0

C02589/1

Holding brake: Closing time

100 ms

C02589/2

Holding brake: Release time

100 ms

C02589/3

Holding brake: Waiting time status

100 ms

C02589/4

Holding brake: Ramp FF control

0 ms

C02593/1

Holding brake: Actual value monitoring

0.000 ms

C02593/2

Holding brake: Application delay

0.000 ms

C02610/1

MCK: Holding brake ramp time synchr.

2.000 s

C02607

Holding brake: Status

-

C00830/68

MCK: nMBrakeAddValue_a

- %

C00833/80

MCK: bMBrakeRelease

-

C00833/81

MCK: bMBrakeStartValue2

-

C00833/82

MCK: bMBrakeApplied

-

Highlighted in grey = display parameter