C00219 | identity, C00220, C00221 – Lenze 8400 User Manual

Page 792: 16 parameter reference

Advertising
background image

16

Parameter reference

16.2

Parameter list | C00205

792

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00205

C00206

C00210

C00219

C00220

C00221

Parameter | Name:

C00205 | Info

Data type: VISIBLE_STRING

Index: 24370

d

= 5F32

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00206 | Production date

Data type: VISIBLE_STRING

Index: 24369

d

= 5F31

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00210 | HW version

Data type: VISIBLE_STRING

Index: 24365

d

= 5F2D

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00219 | Identity

Data type: UNSIGNED_32

Index: 24356

d

= 5F24

h

From version 12.00.00

Display range

(min. value | unit | max. value)

0

4294967295

Subcodes

Info

C00219/1

CAN manufacturer no.

C00219/2

CAN device type

C00219/3

CAN version

C00219/4

CAN count no.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00220 | L_NSet_1: Acceleration time - add. setpoint

Data type: UNSIGNED_32

Index: 24355

d

= 5F23

h

The

L_NSet_1

FB: Acceleration time for the additional setpoint nNAdd_a

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

999.999 0.000 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00221 | L_NSet_1: Deceleration time - add. setpoint

Data type: UNSIGNED_32

Index: 24354

d

= 5F22

h

The

L_NSet_1

FB: Deceleration time for the additional setpoint nNAdd_a

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

999.999 0.000 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000