Counter
This function is a digital upcounter and downcounter with a comparison operation.
[7-25] GeneralPurpose function "Counter"
• Only available with
• For a detailed functional description see FB
.
bGPCounter1Equal
bGPCounter1ClkDown
wGPCounter1LdVal
bGPCounter1Load
wGPCounter1CmpVal
bGPCounter1ClkUp
wGPCounter1Out
C01100
1
3
4
2
Function
C01101
Parameter
Info
Lenze setting
Value Unit
L_Counter_1: Function
0: Normal counting
L_Counter_1: Comparison
0: Greater than or equal to