How to optimise the speed controller setting by means of the ramp response:

1. Run a typical speed profile and record the ramp response of the speed using the data

logger.

• Motor control variables to be recorded:

nSpeedSetValue_a (speed setpoint)

nMotorSpeedAct_a (actual speed value)

2. Evaluate the ramp response:

• Solid line = ramp response (actual speed value)
• Dash line = speed setpoint

3. Change gain Vp in

C00070/2

and reset time Tn in

C00071/2

.

4. Repeat steps 1 ... 3 until the optimum ramp response is reached.

n

t

n

t

n

t

n

t

n

t

n

t

n

t

n

t

n

t

Vp < Vp opt.

Vp = Vp opt.

Vp > Vp opt.

Tn

<

T

n

opt.

Tn

=

T

n

opt.

Tn

>

T

n

opt.