Xx.0184.00001, Xx.0184.00002, Xx.0184.00007 – Lenze 8400 User Manual

Page 605: Xx.0184.00008, Xx.0184.00005, 9diagnostics & error management

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

605

9

Diagnostics & error management

9.10

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Ck01: Pos. HW limit switch [xx.0184.00001]

Ck02: Neg. HW limit switch [xx.0184.00002]

Ck15: Error status sign. brake [xx.0184.00005]

Ck03: Pos. SW limit position [xx.0184.00007]

Ck04: Neg. SW limit position [xx.0184.00008]

Response (Lenze setting printed in bold)

Setting:

C00595/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The hardware limit switch in positive traversing

direction has tripped.

• The bLimitSwitchPos input for travel range

monitoring via positive hardware limit switch has

been set to FALSE (fail-safe).

Reset error message and retract limit switch.

Response (Lenze setting printed in bold)

Setting:

C00595/2

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The hardware limit switch in negative traversing

direction has tripped.

• The bLimitSwitchNeg input for travel range

monitoring via negative hardware limit switch has

been set to FALSE (fail-safe).

Reset error message and retract limit switch.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The status monitoring of the holding brake control

has tripped.

• Check configuration of the bMBrakeApplied input for

status detection of the brake (via a switching contact

at the brake).

• Check wiring/function of the switching contact.

• Adapt waiting time (

C02589/3

).

• Deactivate status monitoring (via bit 5 in

C02582

).

Response (Lenze setting printed in bold)

Setting:

C00595/3

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The device has detected that the position is outside

the positive software limit position (

C01229/1

).

• Increase permissible traversing range (change setting

of the software limit positions).

• Deactivate software limit position monitoring.

Response (Lenze setting printed in bold)

Setting:

C00595/4

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The device has detected that the position is outside

the negative software limit position (

C01229/2

).

• Increase permissible traversing range (change setting

of the software limit positions).

• Deactivate software limit position monitoring.

Advertising