Oc5: ixt overload, Oc7: motor overcurrent, Ot1: maximum torque reached – Lenze 8400 User Manual

Page 591: Xx.0119.00050, Xx.0123.00007, Xx.0119.00016, Xx.0123.00001, 9diagnostics & error management

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

591

9

Diagnostics & error management

9.10

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

oH5: Brake resistor temperature (X20) tripped [xx.0119.00016]

oC5: Ixt overload [xx.0119.00050]

ot1: Maximum torque reached [xx.0123.00001]

oC7: Motor overcurrent [xx.0123.00007]

Response (Lenze setting printed in bold)

Setting:

C00587/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The brake resistor temperature monitoring at plug X20

has been tripped.

Possible causes:

• The external brake resistor is overheated so that the

thermal contact integrated in the brake resistor has

been switched.

• An open circuit or a loose contact at the connections

mentioned above has occurred.

• Check brake resistor temperature monitoring.

• Provide for sufficient cooling of the external brake

resistor.

• Check terminals for open circuit or loose contact.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The Ixt overload check has tripped.

Possible causes:

• Wrong dimensioning of the device with regard to its

motor load.

• Load cycles are not complied with.

• Check and, if required, correct dimensioning of the

device and the motor load with regard to technical

data.

• Reduce motor load cycles (observe load cycles

according to documentation).

Response (Lenze setting printed in bold)

Setting:

C00608

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device indicates that the maximally possible torque

at the motor shaft has been reached.

C00057

displays the current torque.

Reduce motor load.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The maximum current monitoring has tripped.

Check and, if required, correct dimensioning of the load

with regard to the installed device power.