C00580 | resp. to operating system error, C00581 | resp. to ls_seterror_x, C00582 – Lenze 8400 User Manual

Page 850: In the lenze setting, no, C00581/1, C00581/2, C00581/3, C00581/4, C00581/5, C00581/6

Advertising
background image

16

Parameter reference

16.2

Parameter list | C00580

850

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00580

C00581

C00582

Parameter | Name:

C00580 | Resp. to operating system error

Data type: UNSIGNED_8

Index: 23995

d

= 5DBB

h

From version 12.00.00

Selection list

Info

0 No Reaction
1 Fault
5 Warning

Subcodes

Lenze setting

Info

C00580/1

0: No Reaction

Resp. to runtime exceedance

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00581 | Resp. to LS_SetError_x

Data type: UNSIGNED_8

Index: 23994

d

= 5DBA

h

Selection of the error responses for application error messages

• An application error message is tripped by a FALSE/TRUE edge at the binary inputs bSetError1...4.

Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C00581/1

0: No Reaction

LS_SetError_1

: Resp. to bSetError1

C00581/2

0: No Reaction

LS_SetError_1

: Resp. to bSetError2

C00581/3

0: No Reaction

LS_SetError_1

: Resp. to bSetError3

C00581/4

0: No Reaction

LS_SetError_1

: Resp. to bSetError4

C00581/5

0: No Reaction

LS_SetError_2

: Resp. to bSetError1

C00581/6

0: No Reaction

LS_SetError_2

: Resp. to bSetError2

C00581/7

0: No Reaction

LS_SetError_2

: Resp. to bSetError3

C00581/8

0: No Reaction

LS_SetError_2

: Resp. to bSetError4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00582 | Resp. to heatsink temp. > shutdown temp. -5°C

Data type: UNSIGNED_8

Index: 23993

d

= 5DB9

h

Response if the heatsink temperature has reached the switch-off temperature threshold.
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising